Servotest converts Team CUBE™ in record time!
Working on behalf of a leading automotive contract testing laboratory Servotest has successfully completed the conversion and rebuild of a Team CUBE within a 5-week planned down-time period.
The task set by our customer was to increase the reliabiity and reduce the cost-of-ownership of their system. Of particular focus were the noise levels and maintainability concerns relating to the high-peformance voice-coil servovalves used to drive the system.
While this type of servovalve offers high-frequency (>100Hz) performance this is at the cost of significantly increased complexity, both in terms of operation and maintenance. Furthermore these valves generate significant levels of 'noise', both audibly and within the test data.
Since, in this customer's automotive test applications test fequencies rarely exceed 100 Hz, the decision was made to to replace the voice-coil valves with MOOG G761-3055 2-stage servovalves. These have a rated flow of 65 litres per minute and give almost identical performance to the original voice-coil valves up to 100Hz. However, these also offer significantly lower noise levels and excellent control/axis matching.
Servotest was able to exceed the customers expectation both in terms of performance and timing. The system was converted and right back in the lab running a test, with its near-silent two-stage valves, within the planned down-time windo.
Do you have a high maintenance CUBE? Do you need it converted to a low-cost customer-maintainable unit? ...if so then contact us at our Egham office.
CURRENT NEWS
Pulsar 2.0 Software Release
Servotest is excited to announce the release of Pulsar 2 software*, featuring several productive enhancements:
READ MORE - USB 3.0: Supports 'Super-Speed' data transfers.
- Windows 11: Fully supported operating s...
Servotest announce the renewal of ISO9001:2015; ISO14001:2015 & ISO45001:2018 certifications
Servotest Testing Systems is proud to announce the renewal of ISO9001:2015; ISO14001:2015 & ISO45001:2018 certificationsby BSI for the Quality, Environmental, and Health and Safety Management Systems ...
READ MORE Laboratory for Verification & Validation (LVV) opens in Sheffield
The three new research centres opening at The University of Sheffield - the Laboratory for Verification and Validation (LVV), the Royce Translational Centre (RTC) and the Integrated Civil and Infrastr...
READ MORE 
WOULD YOU LIKE TO DISCUSS A PROJECT?
CONTACT USINFO CENTRE
Access Servotest information guides, brochure and videos.

SERVOTEST INFO
Servotest Testing Systems Ltd
Unit 2, Alpha Way
Thorpe Industrial Estate
Egham Surrey
TW20 8RZ
Registered in England & Wales No: 6274550
Vat No. GB 910 1840 66.
Unit 2, Alpha Way
Thorpe Industrial Estate
Egham Surrey
TW20 8RZ
Registered in England & Wales No: 6274550
Vat No. GB 910 1840 66.